{"id":2472,"date":"2025-03-04T08:06:25","date_gmt":"2025-03-04T08:06:25","guid":{"rendered":"https:\/\/www.esdgate.com\/?p=2472"},"modified":"2025-09-20T09:17:37","modified_gmt":"2025-09-20T09:17:37","slug":"esd-flooring","status":"publish","type":"post","link":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/","title":{"rendered":"ESD-Bodenbel\u00e4ge: Die wichtigsten Fakten, die Sie wissen m\u00fcssen"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Was ist ein ESD-Bodenbelag?<\/h2>\n\n\n\n<p>ESD-Bodenbel\u00e4ge sind spezielle Bodenbel\u00e4ge, die statische Elektrizit\u00e4t durch die Verwendung leitf\u00e4higer oder ableitender Materialien sicher ableiten und so Sch\u00e4den an der Elektronik verhindern. Zu den g\u00e4ngigen Typen geh\u00f6ren Vinyl-, Gummi- und Epoxidharzb\u00f6den.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Wie funktioniert ein ESD-Bodenbelag?<\/h2>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png\" alt=\"\" class=\"wp-image-2477 size-full\" srcset=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png 500w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work--300x300.png 300w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work--150x150.png 150w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work--12x12.png 12w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>ESD-Bodenbel\u00e4ge schaffen einen kontrollierten Weg zur sicheren Ableitung von <em><strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Static_electricity\">statische Elektrizit\u00e4t<\/a><\/strong><\/em>und verhindert deren Aufbau. Es besteht aus leitf\u00e4higen Materialien wie Kohlenstofffasern oder Metallfasern, die elektrische Ladungen sicher vom K\u00f6rper zum Boden leiten.<\/p>\n\n\n\n<p>Einige ESD-B\u00f6den sind dissipativ, d. h. sie geben statische Ladungen langsam ab, um einen Aufbau zu verhindern, und verwenden Materialien mit spezifischem elektrischem Widerstand, um Leitf\u00e4higkeit und Sicherheit in Einklang zu bringen.<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Brauche ich einen ESD-Bodenbelag?<\/h2>\n\n\n\n<p>Ob Sie einen ESD-Bodenbelag (Electrostatic Discharge) ben\u00f6tigen, h\u00e4ngt von Ihrer Umgebung und Ihren T\u00e4tigkeiten ab. ESD-Bodenbel\u00e4ge sind unerl\u00e4sslich in Bereichen mit <a href=\"https:\/\/www.esdgate.com\/de\/esd-empfindliche-gerate\/\"><em><strong><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0066ff\" class=\"has-inline-color\">empfindliche elektronische Ger\u00e4te<\/mark><\/strong><\/em><\/a>wie z. B. Rechenzentren, Labors oder Produktionsst\u00e4tten, um statische Sch\u00e4den zu vermeiden. Wenn Sie bei Ihrer Arbeit mit statisch empfindlichen Bauteilen hantieren oder in einer Umgebung arbeiten, die zu statischer Aufladung neigt, ist ein ESD-Boden erforderlich. Andernfalls ist er m\u00f6glicherweise nicht erforderlich.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Welcher Bodenbelag ist f\u00fcr die statische Kontrolle geeignet?<\/h2>\n\n\n\n<p>Zu den gebr\u00e4uchlichen Materialien f\u00fcr elektrostatische Bodenbel\u00e4ge geh\u00f6ren Vinyl-, Gummi- und Epoxidbeschichtungen, die h\u00e4ufig mit leitf\u00e4higen Elementen wie Kohlenstoff oder Kupfer versehen sind, um statische Elektrizit\u00e4t abzuleiten. <\/p>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"600\" src=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/What-flooring-is-suitable-for-static-control.webp\" alt=\"\" class=\"wp-image-2493 size-full\" srcset=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/What-flooring-is-suitable-for-static-control.webp 750w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/What-flooring-is-suitable-for-static-control-300x240.webp 300w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/What-flooring-is-suitable-for-static-control-15x12.webp 15w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Viele Menschen glauben f\u00e4lschlicherweise, dass antistatische Bodenbel\u00e4ge die Entstehung statischer Elektrizit\u00e4t verhindern. In Wirklichkeit enthalten diese B\u00f6den leitf\u00e4hige Fasern und werden mit Kupferfolie unter ihnen verlegt, wobei leitf\u00e4hige Klebstoffe verwendet werden. Die Kupferfolie ist mit zuvor vergrabenen Erdungsleitern verbunden, so dass statische Aufladungen sicher in die Erde abgeleitet werden k\u00f6nnen.<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Wie misst man den ESD-Boden?<\/h2>\n\n\n\n<p>Die Leistung von ESD-B\u00f6den wird anhand von zwei kritischen Tests bewertet: <strong>elektrischer Widerstand<\/strong> (gem\u00e4\u00df ANSI\/ESD STM7.1 oder IEC 61340-4-1) und <strong>Ladungserzeugung<\/strong> (gem\u00e4\u00df ANSI\/ESD STM97.2 oder IEC 61340-4-5).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Messung des elektrischen Widerstands des ESD-Bodens (STM7.1\/IEC 61340-4-1)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Misst die F\u00e4higkeit des Bodens, statische Ladungen abzuleiten.<\/li>\n\n\n\n<li>Verwendet ein Widerstandsmessger\u00e4t (Ohmmeter) mit genormten Elektroden.<\/li>\n\n\n\n<li>Tests <strong>Punkt-zu-Punkt<\/strong> (Rtt) und <strong>Punkt-zu-Erde<\/strong> (Rtg) Widerstand.<\/li>\n\n\n\n<li>Einhaltung: Rtt und Rtg sollten normalerweise zwischen <strong>10^5 \u03a9 und 10^9 \u03a9<\/strong><\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"920\" height=\"450\" src=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-to-measure-esd-floor2.jpg\" alt=\"\" class=\"wp-image-2524\" style=\"width:638px;height:auto\" srcset=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-to-measure-esd-floor2.jpg 920w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-to-measure-esd-floor2-300x147.jpg 300w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-to-measure-esd-floor2-768x376.jpg 768w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-to-measure-esd-floor2-18x9.jpg 18w\" sizes=\"auto, (max-width: 920px) 100vw, 920px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><strong>Ladungserzeugung (STM97.2\/IEC 61340-4-5)<\/strong><\/h3>\n\n\n\n<ul start=\"1\" class=\"wp-block-list\">\n<li>Bewertet die statische Aufladung, die durch die Fu\u00dfreibung auf dem Boden entsteht.<\/li>\n\n\n\n<li>Simuliert das Gehen mit einer standardisierten Testmethode (z. B. Ziehen eines Testschuhs unter kontrollierten Bedingungen).<\/li>\n\n\n\n<li>Misst die Spannung mit einem ber\u00fchrungslosen elektrostatischen Voltmeter.<\/li>\n\n\n\n<li>Einhaltung der Vorschriften: Die erzeugte Spannung sollte folgende Werte nicht \u00fcberschreiten&nbsp;<strong>\u00b1100 Volt<\/strong>&nbsp;(f\u00fcr hochsensible Umgebungen) oder&nbsp;<strong>\u00b1200 Volt<\/strong>&nbsp;(allgemeine ESD-Bereiche).<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Testverfahren wie folgt<\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"920\" height=\"450\" src=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff082\uff09.png\" alt=\"\" class=\"wp-image-2529\" style=\"width:626px;height:auto\" srcset=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff082\uff09.png 920w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff082\uff09-300x147.png 300w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff082\uff09-768x376.png 768w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff082\uff09-18x9.png 18w\" sizes=\"auto, (max-width: 920px) 100vw, 920px\" \/><\/figure>\n<\/div>\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Einrichtung<\/strong>: Tragen Sie <a href=\"https:\/\/www.esdgate.com\/de\/esd-schuhprufgerat\/\"><em><strong><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0066ff\" class=\"has-inline-color\">antistatisches Schuhwerk<\/mark><\/strong><\/em><\/a>Stand auf ESD-Boden. Konfigurieren Sie die Ger\u00e4teparameter.<\/li>\n\n\n\n<li><strong>Messung<\/strong>: Halten Sie die Handelektrode an das K\u00f6rperspannungsmesssystem angeschlossen.<\/li>\n\n\n\n<li><strong>Gehtest<\/strong>:\n<ul class=\"wp-block-list\">\n<li>F\u00fchren Sie die 6-Schritte-Methode auf dem antistatischen Boden durch: linker Fu\u00df auf den Punkten 1, 3, 5 und rechter Fu\u00df auf den Punkten 2, 4, 6, und wiederholen Sie den Zyklus bis zum Abschluss. <\/li>\n\n\n\n<li>Messen Sie mindestens 5 Punkte pro 500 Quadratmeter, so dass auch bei kleineren Fl\u00e4chen mindestens 5 Punkte erfasst werden.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"920\" height=\"450\" src=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff083\uff09.png\" alt=\"\" class=\"wp-image-2530\" srcset=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff083\uff09.png 920w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff083\uff09-300x147.png 300w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff083\uff09-768x376.png 768w, https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/measure-ESD-floor-per-STM97.2-\uff083\uff09-18x9.png 18w\" sizes=\"auto, (max-width: 920px) 100vw, 920px\" \/><\/figure>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Was ist ein ESD-Bodenbelag? ESD-Bodenbel\u00e4ge sind spezielle Bodenbel\u00e4ge, die statische Elektrizit\u00e4t durch die Verwendung leitf\u00e4higer oder ableitender Materialien sicher ableiten und so Sch\u00e4den an der Elektronik verhindern. Zu den g\u00e4ngigen Typen geh\u00f6ren Vinyl-, Gummi- und Epoxidharzb\u00f6den. Wie funktioniert ein ESD-Bodenbelag? ESD-Bodenbel\u00e4ge schaffen einen kontrollierten Weg zur sicheren Ableitung von [...]<\/p>","protected":false},"author":1,"featured_media":2477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[40],"class_list":["post-2472","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-esd-floor"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ESD Flooring: Key Facts You Need to Know | ESD Defender<\/title>\n<meta name=\"description\" content=\"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ESD Flooring: Key Facts You Need to Know | ESD Defender\" \/>\n<meta property=\"og:description\" content=\"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/\" \/>\n<meta property=\"og:site_name\" content=\"ESD Turnstile Gate System - ESD Defender\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-04T08:06:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-20T09:17:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alberto Novack\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alberto Novack\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/\",\"url\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/\",\"name\":\"ESD Flooring: Key Facts You Need to Know | ESD Defender\",\"isPartOf\":{\"@id\":\"https:\/\/www.esdgate.com\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png\",\"datePublished\":\"2025-03-04T08:06:25+00:00\",\"dateModified\":\"2025-09-20T09:17:37+00:00\",\"author\":{\"@id\":\"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/d0889f614774991891bae262c4babf8a\"},\"description\":\"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage\",\"url\":\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png\",\"contentUrl\":\"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png\",\"width\":500,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/www.esdgate.com\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ESD Flooring: Key Facts You Need to Know\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.esdgate.com\/de\/#website\",\"url\":\"https:\/\/www.esdgate.com\/de\/\",\"name\":\"ESD Turnstile Gate System - ESD Defender\",\"description\":\"ESD Turnstile Gate: ESD Testing: Your Essential Shield Against Static Risks!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.esdgate.com\/de\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/d0889f614774991891bae262c4babf8a\",\"name\":\"Alberto Novack\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/69884fec6da95f8b195509d0fb234c6a6e88d44859dda3c6dfff4abcdda6be21?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/69884fec6da95f8b195509d0fb234c6a6e88d44859dda3c6dfff4abcdda6be21?s=96&d=mm&r=g\",\"caption\":\"Alberto Novack\"},\"sameAs\":[\"https:\/\/www.esdgate.com\"],\"url\":\"https:\/\/www.esdgate.com\/de\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ESD Flooring: Key Facts You Need to Know | ESD Defender","description":"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/","og_locale":"de_DE","og_type":"article","og_title":"ESD Flooring: Key Facts You Need to Know | ESD Defender","og_description":"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.","og_url":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/","og_site_name":"ESD Turnstile Gate System - ESD Defender","article_published_time":"2025-03-04T08:06:25+00:00","article_modified_time":"2025-09-20T09:17:37+00:00","og_image":[{"width":500,"height":500,"url":"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png","type":"image\/jpeg"}],"author":"Alberto Novack","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Alberto Novack","Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/","url":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/","name":"ESD Flooring: Key Facts You Need to Know | ESD Defender","isPartOf":{"@id":"https:\/\/www.esdgate.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage"},"image":{"@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage"},"thumbnailUrl":"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png","datePublished":"2025-03-04T08:06:25+00:00","dateModified":"2025-09-20T09:17:37+00:00","author":{"@id":"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/d0889f614774991891bae262c4babf8a"},"description":"Learn key facts about ESD flooring\u2014types, benefits, and installation tips. Ensure static control and safety for your ESD sensitive workspace.","breadcrumb":{"@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#primaryimage","url":"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png","contentUrl":"https:\/\/www.esdgate.com\/wp-content\/uploads\/2025\/03\/how-does-ESD-flooring-work-.png","width":500,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.esdgate.com\/de\/esd-bodenbelag\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.esdgate.com\/de\/"},{"@type":"ListItem","position":2,"name":"ESD Flooring: Key Facts You Need to Know"}]},{"@type":"WebSite","@id":"https:\/\/www.esdgate.com\/de\/#website","url":"https:\/\/www.esdgate.com\/de\/","name":"ESD Turnstile Gate System - ESD Defender","description":"ESD Turnstile Gate: ESD Testing: Your Essential Shield Against Static Risks!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.esdgate.com\/de\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/d0889f614774991891bae262c4babf8a","name":"Alberto Novack","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.esdgate.com\/de\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/69884fec6da95f8b195509d0fb234c6a6e88d44859dda3c6dfff4abcdda6be21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/69884fec6da95f8b195509d0fb234c6a6e88d44859dda3c6dfff4abcdda6be21?s=96&d=mm&r=g","caption":"Alberto Novack"},"sameAs":["https:\/\/www.esdgate.com"],"url":"https:\/\/www.esdgate.com\/de\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/posts\/2472","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/comments?post=2472"}],"version-history":[{"count":19,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/posts\/2472\/revisions"}],"predecessor-version":[{"id":3120,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/posts\/2472\/revisions\/3120"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/media\/2477"}],"wp:attachment":[{"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/media?parent=2472"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/categories?post=2472"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.esdgate.com\/de\/wp-json\/wp\/v2\/tags?post=2472"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}